VKDIM - DUAL BLOCK® 2-way ball valve DN 10:50

DUAL BLOCK® 2-way ball valve with female ends for socket welding, metric series.

FIP has developed a VKD DUAL BLOCK® ball valve to introduce a high reference standard in thermosplastic valve design. VKD is a True Union ball valve that meets the most stringent needs required by industrial applications.

Main features:

  • Ergonomic HIPVC handle equipped with removable tool to adjust the ball seat carrier.
  • Handle lock 0°- 90° SHKD (available as an accessory) ergonomically operable during service and padlockable
  • Robust integrated bracket for valve anchoring, for easy and quick automation even after valve installation on the system via the Power Quick module (optional)
  • DUAL BLOCK® patented lock system that ensures union nut tightening hold even in severe conditions such as vibrations or heat dilation
  • Machined high surface finish ball that guarantees a smooth operation and increased reliability
Go back Data sheet

EPDM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016E 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020E 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025E 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032E 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040E 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050E 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063E 63 50 10 108 62 134 76 122 199 111 144 1166

EPDM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016E0LF 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020E0LF 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025E0LF 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032E0LF 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040E0LF 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050E0LF 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063E0LF 63 50 10 108 62 134 76 122 199 111 144 1166

EPDM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016E0SF 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020E0SF 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025E0SF 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032E0SF 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040E0SF 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050E0SF 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063E0SF 63 50 10 108 62 134 76 122 199 111 144 1166

FKM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016F 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020F 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025F 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032F 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040F 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050F 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063F 63 50 10 108 62 134 76 122 199 111 144 1166

FKM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016F0LF 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020F0LF 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025F0LF 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032F0LF 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040F0LF 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050F0LF 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063F0LF 63 50 10 108 62 134 76 122 199 111 144 1166

FKM

Reference d DN PN B B1 C C1 E H H1 Z g
VKDIM016F0SF 16 10 10 54 29 67 40 54 102 65 74,5 150
VKDIM020F0SF 20 15 10 54 29 67 40 54 102 65 73 145
VKDIM025F0SF 25 20 10 65 34,5 85 49 65 114 70 82 218
VKDIM032F0SF 32 25 10 69,5 39 85 49 73 126 78 90 298
VKDIM040F0SF 40 32 10 82,5 46 108 64 86 141 88 100 480
VKDIM050F0SF 50 40 10 89 52 108 64 98 164 93 117 682
VKDIM063F0SF 63 50 10 108 62 134 76 122 199 111 144 1166
  • Connection system for solvent weld, threaded and flanged joints
  • Patented SEAT STOP® ball carrier system that lets you micro-adjust ball seats and minimise the axial force effect
  • Easy radial dismounting allowing quick replacement of O-rings and ball seats without any need for tools
  • PN16 True Union valve body made for rigid PVC-U injection moulding equipped with built-in bores for actuation. ISO 9393 compliant test requisites
  • Option of dismounting downstream pipes with the valve in the closed position
  • Floating full bore ball with high surface finish
  • Integrated bracket for valve anchoring
  • Ball seat carriers can be adjusted using the Easytorque adjustment kit
  • Possibility to have handle with integrated LSQT limit micro switch, even as a retrofit in existing installations