FKOA/RM - BUTTERFLY VALVE

Gearbox operated Butterfly valve.

The FK is a butterfly valve for shutting off or regulating flow, with structural characteristics that make it ideal for industrial applications requiring high performance and longterm reliability. This$valve is also equipped with the customisable Labelling System.

Main features:

  • Ergonomic handle in HIPVC equipped with locking and unlocking device, release, quick operation and graduated adjustment in 10 intermediate positions (DN 40÷200). The operating range, starting from the first few degrees of valve opening, also guarantees extremely low pressure drops.
  • Customisable Labelling System: integrated module in the handle, made of a transparent protection plug and a customisable tag holder using the LSE set (available as an accessory). The customisation lets you identify the valve on the system according to specific needs.
  • STAINLESS steel square section stem completely isolated from the fluid complying with standard£ISO 5211:£DN 40÷65: 11 mm£DN 80÷100: 14 mm£DN 125÷150: 17 mm£DN 200: 22 mm£DN 250÷300: 27 mm
  • Body in polypropylene based compound reinforced with fibreglass (PP-GR) resistant to UV rays and characterised by high mechanical strength.
  • Drilling pattern using oval slots that allow coupling to flanges according to numerous international standards. The special self-centring inserts in ABS supplied for DN 40÷200 guarantee the correct axial alignment of the valve during installation. For DN 250÷400 valves, the drilling pattern for the selfcentring system is of the traditional type according to DIN and ANSI standards.
  • Interchangeable liner with the dual function of forming a hydraulic seal and isolating the body from the fluid.
Go back Data sheet

EPDM

Reference d - Size DN PN A min A max øA B2 B[5:5] B[5:6] G G[5:1] G[5:2] G[5:3] H U Z g
FKOARM075E 75 - 2"1/2 65 10 128 144 - 80 174 146 48 135 39 125 165 4 46 2608
FKOARM090E 90 - 3" 80 10 145 160 - 93 188 160 48 135 39 125 185 12 49 3063
FKOARM110E 110 - 4" 100 10 165 190 - 107 202 174 48 135 39 125 211 8 56 3481
FKOARM140E 140 - 5" 125 10 204 215 - 120 222 194 48 144 39 200 240 8 64 4434
FKOARM160E 160 - 6" 150 10 230 242 - 134 235 207 48 144 39 200 268 8 70 5299
FKOARM225E 225 200 10 280 298 - 161 287 256 65 204 60 200 323 8 71 8945
FKOARM280E 280 *250 10 335 362 350 210 317 281 88 236 76 250 405 8 114 18727
FKOARM315E 315 *300 8 390 432 400 245 374 338 88 236 76 250 475 12 114 23004

FKM

Reference d - Size DN PN A min A max øA B2 B[5:5] B[5:6] G G[5:1] G[5:2] G[5:3] H U Z g
FKOARM075F 75 - 2"1/2 65 10 128 144 - 80 174 146 48 135 39 125 165 4 46 2608
FKOARM090F 90 - 3" 80 10 145 160 - 93 188 160 48 135 39 125 185 12 49 3063
FKOARM110F 110 - 4" 100 10 165 190 - 107 202 174 48 135 39 125 211 8 56 3481
FKOARM140F 140 - 5" 125 10 204 215 - 120 222 194 48 144 39 200 240 8 64 4434
FKOARM160F 160 - 6" 150 10 230 242 - 134 235 207 48 144 39 200 268 8 70 5299
FKOARM225F 225 200 10 280 298 - 161 287 256 65 204 60 200 323 8 71 8945
FKOARM280F 280 *250 10 335 362 350 210 317 281 88 236 76 250 405 8 114 18727
FKOARM315F 315 *300 8 390 432 400 245 374 338 88 236 76 250 475 12 114 23004
  • Interchangeable Disk in PVC-C with through shaft, available in different thermoplastic materials: PVC-U, PP-H, ABS, PVDF
  • Overall dimensions of the valve in accordance with standard ISO 5752 (DN 40÷200 Medium Series 25, DN 250÷ 300 Long Series 16) and DIN 3202 K2 and ISO 5752 (DN 65÷200 K2, DN 250÷300 K3)
  • Can also be installed as an end line valve, bottom discharge valve or tank dump valve
  • Special Lug version PN 10 fully drilled to DIN 2501 or ANSI B16.5 cl.150 with molded-in AISI 316 stainless steel threaded inserts
  • Possibility of installing a manual reducer or pneumatic and/or electric actuators by applying ISO standard drilling pattern PP-GR flanges. DN 40 ÷ 200 valve fitted with plate with rack in PP-GR. For actuated versions with flange drilled according to ISO 5211 F05, F07, F10
  • DN 250÷300 valve, fitted with one-piece top flange in high mechanical strength PP-GR with mounting flange for internal components with drilling according to standard ISO 5211 F10, F12, F14
  • Possibility to have handle with integrated LSQT limit micro switch, even as a retrofit in existing installations